Mangafodipir trisodyum ile pankreas malign kitlelerinin değerlendirilmesi

dc.contributor.authorArgımak, Yasin
dc.contributor.authorTemizöz, Osman
dc.contributor.authorTosun, Alptekin
dc.contributor.authorÇakır, Bilge
dc.date.accessioned2021-11-20T10:11:46Z
dc.date.available2021-11-20T10:11:46Z
dc.date.issued2009
dc.departmentFakülteler, Tıp Fakültesi, Dahili Tıp Bilimleri Bölümü, Radyoloji Anabilim Dalıen_US
dc.description.abstractAmaç: Organ spesifik ajan olan mangafodipir trisodyum (Mn-DPDP) kullanılarak yapılan manyetik rezonans görüntülemenin pankreas malign kitlelerinin incelenmesinde tanısal etkinliğini incelemek. Hastalar ve Yöntemler: Abdominal ultrasonografi ve bilgisayarlı tomografi bulguları ile pankreas tümörü düşünülen 17 hastanın (7 kadın, 10 erkek; ort. yaş 63.2±12; dağılım 36-80) manyetik rezonans görüntüleri, T1A SE, yağ baskılı T1A SE ve T1A GRE sekanslarının kullanımı ile sinyal-gürültü (S/N) ve kontrast-gürültü (C/N) oranları açısından Mn-DPDP uygulaması öncesi ve sonrası incelendi. Bulgular: Kontrast öncesi ve sonrası incelemelerde normal pankreasın S/N oranlarında artış T1A SE sekansta ortalama %22.81, yağ baskılı T1A SE sekansında %32.88 ve T1A GRE sekansında %20 olarak bulundu. Normal pankreas dokusu ve tümör kitlesi sinyal intensite değerlerinden hesaplanan C/N oranında ise yüzde artış T1A SE sekansı için ortalama %58.69, yağ baskılı T1A SE sekansta %125.41 ve T1A GRE sekansta %62.06 olarak saptandı. Ayrıca uygulanan sinyal intensite ölçümlerine göre her üç sekansta elde edilen kontrast öncesi ve sonrası C/N oranlarındaki artış istatistiksel olarak anlamlı idi (paired Student t testi p<0.0001). Sonuç: Kontrast madde olarak Mn-DPDP'nin kullanımı ile C/N oranlarındaki değişim pankreasın malign kitlelerinin incelenmesinde tanıya katkı sağlayabilir.en_US
dc.description.abstractObjectives: Our study aimed to assess the diagnostic capabilities of mangafodipir trisodium (Mn-DPDP)- enhanced magnetic resonance imaging for the evaluation of pancreatic malign mass. Patients and Methods: Magnetic resonance images of 17 patients (7 females, 10 males; mean age 63.2&plusmn;12 years; range 36 to 80 years) suspected of pancreatic tumor by abdominal ultrasonography and computed tomography findings, were examined in terms of signal to noise (S/N) and contrast to noise (C/N) ratios before and after administration of Mn-DPDP using T1 A SE, Fat Sat T1 A SE and GRE T1 A sequences. Results: Before and after administration of Mn-DPDP, the increase in S/N ratios of normal pancreatic parenchyma were found as 22.81%, 32.88% and 20% in T1 A SE, Fat Sat T1 A SE and GRE T1 A sequences, respectively. The increase in C/N ratios obtained from signal intensity values of normal pancreatic tissue and tumor were found as 58.69%, 125.41% and 62.06% in T1 A SE, Fat Sat T1 A SE and GRE T1 A sequences, respectively. Furthermore, in all sequences, before and after contrast medium administration, the increase of C/N ratios were found statistically significant (paired Student's t test, p&lt;0.0001). Conclusion: The differences of C/N ratio using Mn-DPDP as a contrast agent may contribute to the diagnosis of pancreatic malign masses.en_US
dc.identifier.endpage58en_US
dc.identifier.issn1301-3149
dc.identifier.issue1en_US
dc.identifier.startpage53en_US
dc.identifier.trdizinid92540en_US
dc.identifier.urihttps://app.trdizin.gov.tr/makale/T1RJMU5EQXc
dc.identifier.urihttps://hdl.handle.net/20.500.14551/5995
dc.identifier.volume26en_US
dc.indekslendigikaynakTR-Dizinen_US
dc.language.isotren_US
dc.relation.ispartofTrakya Üniversitesi Tıp Fakültesi Dergisien_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.snmz20240608_ID_Qen_US
dc.subjectTıbbi Araştırmalar Deneyselen_US
dc.subjectOrtopedien_US
dc.subjectRadyoloji, Nükleer Tıp, Tıbbi Görüntülemeen_US
dc.titleMangafodipir trisodyum ile pankreas malign kitlelerinin değerlendirilmesien_US
dc.title.alternativeEvaluation of pancreatic malign tumours with mangafodipir trisodiumen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
5995.pdf
Boyut:
205.31 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text