Three-dimensional transesophageal echocardiography vs cardiac magnetic resonance in the assessment of planimetric mitral valve area in rheumatic mitral stenosis

dc.authoridhttp://orcid.org/0000-0002-0340-4487en_US
dc.contributor.authorUygur, Begum
dc.contributor.authorCelik, Omer
dc.contributor.authorUstabasioglu, Fethi Emre
dc.contributor.authorAkinci, Okan
dc.contributor.authorErturk, Mehmet
dc.date.accessioned2019-12-23T11:31:05Z
dc.date.available2019-12-23T11:31:05Z
dc.date.issued2018
dc.departmentFakülteler, Tıp Fakültesi, Dahili Tıp Bilimleri Bölümü, Radyoloji Anabilim Dalıen_US
dc.description.abstractAimRheumatic heart disease is a common cause of valvular disease, especially in developing countries. Echocardiography is the gold standard investigation modality for cardiac valves. In rheumatic mitral stenosis (MS), three-dimensional transesophageal echocardiography (3D TEE) provides better alignment of the image plane at the mitral tips and more accurate and reproducible planimetric measurement of mitral valve area (MVA). Cardiac magnetic resonance (CMR) is a new method that provides evaluation of cardiac anatomy and function noninvasively. Previous studies showed strong correlation between planimetric MVA measured by two-dimensional transthoracic echocardiography and CMR. We aimed to compare the planimetric MVAs assessed by 3D TEE and CMR in rheumatic MS patients. To best of our knowledge, this is the first study that compares 3D TEE and CMR for the assessment of the planimetric MVA in rheumatic MS. MethodsWe retrospectively evaluated 28 rheumatic MS patients who underwent 3D TEE and ECG-gated CMR. 3D TEE planimetric MVAs were measured manually by multiplanar reconstruction (MPR) method and CMR planimetric MVAs were measured manually on short-axis cine images. Then, 3D TEE and CMR measurements were compared. ResultsA total of 28 patients' (mean age 4412, 82.1% female) planimetric 3D TEE MVAs (1.00 +/- 0.20cm(2)) and CMR MVAs (1.04 +/- 0.17cm(2)) were found to be highly correlated (P<0.0001, r: 0.744) with Pearson correlation analysis. Bland-Altman analysis showed strong agreement between two techniques. ConclusionFor the diagnosis and the follow-up of rheumatic MS, planimetric CMR MVA is an alternative noninvasive method which highly correlates with planimetric 3D TEE MVA.en_US
dc.identifier.citationUygur, B., Celik, O., Ustabasioglu, F. E., Akinci, O., & Erturk, M. (2018). Three‐dimensional transesophageal echocardiography vs cardiac magnetic resonance in the assessment of planimetric mitral valve area in rheumatic mitral stenosis. Echocardiography, 35(10), 1621-1625.en_US
dc.identifier.doi10.1111/echo.14096en_US
dc.identifier.endpage1625en_US
dc.identifier.issn0742-2822
dc.identifier.issn1540-8175
dc.identifier.issue10en_US
dc.identifier.pmid29981197en_US
dc.identifier.scopus2-s2.0-85050851514en_US
dc.identifier.scopusqualityQ3en_US
dc.identifier.startpage1621en_US
dc.identifier.urihttps://hdl.handle.net/20.500.14551/4883
dc.identifier.urihttps://doi.org/10.1111/echo.14096
dc.identifier.volume35en_US
dc.identifier.wosWOS:000446559700018en_US
dc.identifier.wosqualityQ4en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.language.isoenen_US
dc.publisherWILEYen_US
dc.relation.ispartofJournal Citation Reportsen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.snmz20240608_ID_Qen_US
dc.subjectCardiac Magnetic Resonance Imagingen_US
dc.subjectMitral Stenosisen_US
dc.subjectMitral Valve Areaen_US
dc.subjectThree-Dimensional Transesophageal Echocardiographyen_US
dc.subjectValvular Heart-Diseaseen_US
dc.subjectManagementen_US
dc.titleThree-dimensional transesophageal echocardiography vs cardiac magnetic resonance in the assessment of planimetric mitral valve area in rheumatic mitral stenosisen_US
dc.typeArticleen_US

Dosyalar

Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: