Technetium-99m sestamibi cavity/myocardium count ratio in the detection of left ventricular hypertrophy

Küçük Resim Yok

Tarih

2003

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Clinical Cardiology Publ Co

Erişim Hakkı

info:eu-repo/semantics/openAccess

Özet

Background and hypothesis: Left ventricular hypertrophy (LVH) is an independent risk factor for cardiovascular mortality and morbidity. This study was designed to assess whether technetium-99m (Tc-99m) sestamibi cavity-to-myocardium count (c/m) ratio would differentiate LVH from normal geometry, and discriminate between the two patterns-concentric and eccentric-of LVH. Methods: In all, 72 patients including 32 hypertensive patients with both normal Tc-99m sestamibi single-photon emission computed tomography imaging and good-quality echocardiographic recordings were studied retrospectively. Four different patterns of left ventricular (LV) geometry were defined: normal (n = 47), concentric remodeling (n = 3), eccentric LVH (n = 13), and concentric LVH (n = 9). Results: Left ventricular hypertrophy was detected in 22 of 32 hypertensive patients. The c/m ratio calculated on midventricular short-axis slices of dipyridamole-stress Tc-99m sestamibi images was significantly decreased in patients with LVH compared with subjects with normal geometry (0.05 +/- 0.02 vs. 0.17 +/- 0.08, p = 0.001). A c/m ratio of < 0.124 yielded a sensitivity of 86%, a specificity of 64%, and an overall diagnostic accuracy of 68% for detecting LVH. Negative correlations of c/m ratio were found to LV mass-index (r = -0.44, p = 0.004), septal width (r = -0.42, p = 0.008), posterior wall thickness (r = -0.39, p = 0.001), and relative wall thickness (r = -0.40, p = 0.001). Multiple linear regression analysis revealed that LV mass index was the single independent predictor of c/m ratio. Although both groups with concentric and eccentric LVH had a significantly lower mean c/m ratio than those with normal geometry (p = 0.01 and p = 0.01, respectively), no significant difference of c/m ratio was found between the two patterns of LVH. Conclusion: A new index, c/m ratio on Tc-99m sestamibi images, has a potential to discriminate between LVH and normal geometry in subjects free of myocardial ischemia.

Açıklama

5th International Conference of Nuclear Cardiology -- MAY, 2001 -- VIENNA, AUSTRIA

Anahtar Kelimeler

Tc-99m Sestamibi, Cavity/Myocardium Count Ratio, Left Ventricular Hypertrophy, Essential-Hypertension, Dysfunction, Patterns, Spect, Mass

Kaynak

Clinical Cardiology

WoS Q Değeri

Q2

Scopus Q Değeri

Q2

Cilt

26

Sayı

3

Künye