The Evaluation of Arterial and Venous Grafts with Intraoperative Flowmeter Techniques in Coronary Artery Bypass Grafting Operations

dc.authorwosidÜnal, Selçuk/HOA-5702-2023
dc.contributor.authorCanbaz, Suat
dc.contributor.authorUnal, Selcuk
dc.contributor.authorDikmengil, Murat
dc.contributor.authorDuran, Enver
dc.date.accessioned2024-06-12T10:58:35Z
dc.date.available2024-06-12T10:58:35Z
dc.date.issued2010
dc.departmentTrakya Üniversitesien_US
dc.description.abstractObjective: The purpose of this study was to evaluate the coronary artery bypass grafts with Transit Time Flowmeter (TTFM). Material and Methods: Fifty-nine patients who were scheduled for coronary artery bypass graft (CABG) surgery were included in the study. Coronary artery bypass anastomoses were performed using the left internal mammary artery (LIMA) and saphenous vein. At the end of the cardiopulmonary bypass, graft flow (ml/min), pulsatility index (PI), flow curve and diastolic filling percentage (DF%) of each graft were assessed with TTFM. Results: Mean graft number of the patients was 3.25+/-0.8. We assessed the patency of a total of 187 grafts using TTFM. Highest mean flow was 55.5 ml/min in aorta-RCA grafts and lowest mean flow was 37.6 ml/min in aorta-diagonal grafts. Revision was required for two grafts (3.38%) in two patients based on inadequate TTFM findings. Conclusion: Transit time flowmeter is an important technique that provides the detection of technical errors during surgery. With the detection of graft failure intraoperatively, revision of the graft and restoration of blood flow could be performed.en_US
dc.identifier.doi10.5174/tutfd.2010.03767.1
dc.identifier.endpage416en_US
dc.identifier.issn1301-3149
dc.identifier.issue4en_US
dc.identifier.scopus2-s2.0-79952081308en_US
dc.identifier.scopusqualityN/Aen_US
dc.identifier.startpage411en_US
dc.identifier.urihttps://doi.org/10.5174/tutfd.2010.03767.1
dc.identifier.urihttps://hdl.handle.net/20.500.14551/20115
dc.identifier.volume27en_US
dc.identifier.wosWOS:000287686200017en_US
dc.identifier.wosqualityQ4en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.language.isotren_US
dc.publisherAves Yayincilik, Ibrahim Karaen_US
dc.relation.ispartofTrakya Universitesi Tip Fakultesi Dergisien_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectCoronary Artery Bypass Graftingen_US
dc.subjectInternal Mammary Arteryen_US
dc.subjectSaphenous Veinen_US
dc.subjectTransit Time Flowmeteren_US
dc.subjectGraft Revisionen_US
dc.subjectTime Flow Measurementen_US
dc.subjectSurgeryen_US
dc.subjectRevascularizationen_US
dc.subjectFailureen_US
dc.subjectPatencyen_US
dc.titleThe Evaluation of Arterial and Venous Grafts with Intraoperative Flowmeter Techniques in Coronary Artery Bypass Grafting Operationsen_US
dc.typeArticleen_US

Dosyalar