Primary Stability in Various Levels of Impacted Implants: An Ex Vivo

dc.authoridÖzyurt, Anıl/0000-0002-3243-3156
dc.authoridBilmenoglu, Caglar/0000-0002-2580-9899
dc.authorwosidÖzyurt, Anıl/AAY-5407-2020
dc.authorwosidBilmenoglu, Caglar/HGE-5706-2022
dc.contributor.authorBilmenoglu, Caglar
dc.contributor.authorOzyurt, Anil
dc.contributor.authorCilingir, Ahmet Altug
dc.contributor.authorTuran, Fatma Nesrin
dc.date.accessioned2024-06-12T11:13:38Z
dc.date.available2024-06-12T11:13:38Z
dc.date.issued2021
dc.departmentTrakya Üniversitesien_US
dc.description.abstractThe aim of this study was to examine the primary stabilization of different vertically impacted bone implants. Implant stability was measured by resonance frequency analysis. Forty-five dental implants were used and divided into 3 groups. Group 1 was placed 4 mm (1/3 impacted), group 2 was placed 8 mm (2/3 impacted), and group 3 was placed 12 mm (fully impacted). Implant stability quotient values were measured on the longitudinal and transversal axis by 2 independent researchers. The fully impacted group showed the significantly highest value among the groups (P , .05). There were statistically varying implant-stability quotient values between researchers. None of the 1/3-impacted implants' value reached a 70 implant-stability quotient value.en_US
dc.identifier.doi10.1563/aaid-joi-D-19-00232
dc.identifier.endpage384en_US
dc.identifier.issn0160-6972
dc.identifier.issn1548-1336
dc.identifier.issue5en_US
dc.identifier.pmid33270883en_US
dc.identifier.scopus2-s2.0-85119485417en_US
dc.identifier.scopusqualityQ2en_US
dc.identifier.startpage380en_US
dc.identifier.urihttps://doi.org/10.1563/aaid-joi-D-19-00232
dc.identifier.urihttps://hdl.handle.net/20.500.14551/23627
dc.identifier.volume47en_US
dc.identifier.wosWOS:000712549400004en_US
dc.identifier.wosqualityQ4en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.language.isoenen_US
dc.publisherAllen Press Incen_US
dc.relation.ispartofJournal Of Oral Implantologyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectRFAen_US
dc.subjectPrimary Stabilityen_US
dc.subjectDental Implanten_US
dc.subjectPartial Impactionen_US
dc.subjectResonance Frequency-Analysisen_US
dc.subjectIn-Vitroen_US
dc.subjectDental Implantsen_US
dc.subjectAesthetic Zoneen_US
dc.subjectReliabilityen_US
dc.subjectImmediateen_US
dc.subjectGeometryen_US
dc.subjectSurfaceen_US
dc.titlePrimary Stability in Various Levels of Impacted Implants: An Ex Vivoen_US
dc.typeArticleen_US

Dosyalar