Superparamagnetic Iron Oxide Enhanced Magnetic Resonance Imaging in the Detection of Malignant Liver Lesions
dc.authorwosid | Umit, Hasan/T-6236-2019 | |
dc.authorwosid | Tosun, Alptekin/AAA-1350-2021 | |
dc.contributor.author | Cagli, Bekir | |
dc.contributor.author | Temizoz, Osman | |
dc.contributor.author | Genchellac, Hakan | |
dc.contributor.author | Umit, Hasan | |
dc.contributor.author | Tosun, Alptekin | |
dc.contributor.author | Cakir, Bilge | |
dc.date.accessioned | 2024-06-12T11:15:49Z | |
dc.date.available | 2024-06-12T11:15:49Z | |
dc.date.issued | 2011 | |
dc.department | Trakya Üniversitesi | en_US |
dc.description.abstract | Objective: To determine the value of superparamagnetic iron oxide (SPIO)-enhanced MR imaging in malignant liver lesions. Materials and Methods: Twenty patients with various hepatic masses or metastases were investigated with 1 tesla MR. T1-weighted FLASH and double- echo TSE T2-weighted sequences were applied before and after contrast injection. Defining statistics were prepared according to pre and postcontrast signal intensity measurements. Results: In this study there were 11 patients with metastases, 4 patients with hemangioma, 4 patients with HCC and one patient with a hemangioma and a metastasis at the same time. In cases wheret we found only hemangiomas, in all sequences, S/N ratios (p=0.043) and T2-weighted double-echo TSE with long TE SI change (p=0.043) were significant. While in the hemangiomas in T2-weighted double-echo TSE with long TE there is an decrease in the C/N ratios; in cases with metastasis and HCC, compared to other sequences significant increase in C/N ratio in T2-weighted double-echo TSE with short TE sequences was detected. Conclusion: SPIO-enhanced MR imaging can be used as a non-invasive radiologic technique for the detection focal liver lesions, to determine the number of lesions and also has a value in differentiating the benign lesions (especially hemangiomas) from primary tumors or metastatic malignant lesions. | en_US |
dc.identifier.endpage | 292 | en_US |
dc.identifier.issn | 2146-3123 | |
dc.identifier.issn | 2146-3131 | |
dc.identifier.issue | 3 | en_US |
dc.identifier.startpage | 286 | en_US |
dc.identifier.uri | https://hdl.handle.net/20.500.14551/24087 | |
dc.identifier.volume | 28 | en_US |
dc.identifier.wos | WOS:000295492900012 | en_US |
dc.identifier.wosquality | N/A | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.language.iso | tr | en_US |
dc.publisher | Galenos Publ House | en_US |
dc.relation.ispartof | Balkan Medical Journal | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Superparamagnetic Iron Oxide (SPIO) | en_US |
dc.subject | Contrast-Noise Ratio | en_US |
dc.subject | MR Imaging | en_US |
dc.subject | T1-Weighted FLASH And T2-Weighted Double-Echo TSE Sequences | en_US |
dc.subject | Focal Hepatic-Lesions | en_US |
dc.subject | Contrast Agents | en_US |
dc.subject | Spiral Ct | en_US |
dc.subject | Mr | en_US |
dc.subject | Ferumoxides | en_US |
dc.subject | Metastases | en_US |
dc.subject | Safety | en_US |
dc.title | Superparamagnetic Iron Oxide Enhanced Magnetic Resonance Imaging in the Detection of Malignant Liver Lesions | en_US |