Evaluation of the Internal and Marginal Discrepancies of Co-Cr Metal Copings Prepared via CAD/CAM and Conventional Casting

Küçük Resim Yok

Tarih

2019

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Dennis Barber Ltd

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Özet

The aim of this study was to assess the internal and marginal discrepancies of chromium-cobalt (Co/Cr) copings fabricated using different techniques. A typodont molar tooth was prepared and replicated in die stone and scanned. Forty Co-Cr alloy copings were produced using four different production techniques: conventional casting (C-group), direct metal laser sintering (DMLS-group), micro-stereolithography/casting combination (mu SLA-group), and computer-aided milling (M-group) (n = 10). The internal and marginal discrepancies at various reference points were determined via digital microscopy. Analysis of variance (ANOVA) and Tukey's multiple comparisons tests were used for statistical analysis (p=0.05). The marginal and cervical discrepancies of the C-group were similar to those of the M-group (p>0.05) and better than those of the mu SLA-group (p<0.05). The marginal and internal discrepancies of all groups were within clinically acceptable limits, but further improvements in the mu SLA and DMLS techniques may be required prior to clinical implementation.

Açıklama

Anahtar Kelimeler

Computer-Aided Design, Alloys, Computer-Aided Manufacture, Marginal Discrepancy, Internal Discrepancy, Fit, Crowns, Adaptation, Accuracy, Future, Gaps

Kaynak

European Journal Of Prosthodontics And Restorative Dentistry

WoS Q Değeri

N/A

Scopus Q Değeri

Q3

Cilt

27

Sayı

1

Künye