Determination of the Optimum Torque to Tighten the Smartpegs of Magnetic Resonance Frequency Analyses Devices: An Ex Vivo Study

dc.authoridBilmenoglu, Caglar/0000-0002-2580-9899
dc.authoridGECKILI, ONUR/0000-0002-7852-3915
dc.authoridCilingir, Altug/0000-0002-0694-5772
dc.authoridBilhan, Hakan/0000-0003-1787-3003
dc.authorwosidBURAL, HAYRUNNİSA CANAN/AAE-1151-2020
dc.authorwosidBilmenoglu, Caglar/HGE-5706-2022
dc.authorwosidGECKILI, ONUR/AAD-4973-2020
dc.authorwosidCilingir, Altug/N-2262-2018
dc.contributor.authorGeckili, Onur
dc.contributor.authorCilingir, Altug
dc.contributor.authorBural, Canan
dc.contributor.authorBilmenoglu, Caglar
dc.contributor.authorBilhan, Hakan
dc.date.accessioned2024-06-12T10:59:21Z
dc.date.available2024-06-12T10:59:21Z
dc.date.issued2015
dc.departmentTrakya Üniversitesien_US
dc.description.abstractThe aim of this study was to find an optimal value for tightening the Smartpegs for magnetic radiofrequency analysis devices (RFAs) devices. Thirty implants were placed in 3 cow ribs. The RFA value of each implant was measured in buccal and mesial directions after tightening the Smartpegs with 1, 3, 4, 8, 9, 10, and 11 Ncm. Additionally, 4 different examiners measured the RFA after hand tightening the Smartpegs, and the results were compared. The buccal implant stability quotient (ISQ) values when the Smartpegs were tightened to 1Ncm were significantly lower than the ISQ values when the Smartpegs were tightened to 3, 4, 8, 9, 10, and 11 Ncm (P<.05). The mesial ISQ values when the Smartpegs were tightened to 1, 3, and 4 Ncm were significantly lower than the ISQ values when the Smartpegs were tightened with higher torque values (P<.05). The buccal measurements made by 1 examiner was significantly lower than 3 Ncm (P<.05), and the buccal measurements made by 1 examiner was significantly lower than 4 Ncm (P<.05). The mesial ISQ values measured by 2 examiners were significantly lower than 3 Ncm (P<.05), and the mesial ISQ values measured by the other 2 examiners were significantly lower than 8 Ncm (P<.05). The tightening of the Smartpegs should be standardized by the manufacturer to a range of 5-8 Ncm in order to gain reliable objective RFA values, instead of leaving it to subjective finger pressure.en_US
dc.identifier.doi10.1563/aaid-joi-D-14-00266
dc.identifier.endpageE256en_US
dc.identifier.issn0160-6972
dc.identifier.issn1548-1336
dc.identifier.issue6en_US
dc.identifier.pmid25668680en_US
dc.identifier.scopus2-s2.0-84949937508en_US
dc.identifier.scopusqualityQ2en_US
dc.identifier.startpageE252en_US
dc.identifier.urihttps://doi.org/10.1563/aaid-joi-D-14-00266
dc.identifier.urihttps://hdl.handle.net/20.500.14551/20389
dc.identifier.volume41en_US
dc.identifier.wosWOS:000366723300003en_US
dc.identifier.wosqualityQ2en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.language.isoenen_US
dc.publisherAllen Press Incen_US
dc.relation.ispartofJournal Of Oral Implantologyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectDental Implantsen_US
dc.subjectRadiofrequency Analysisen_US
dc.subjectOsseointegrationen_US
dc.subjectPrimary Stabilityen_US
dc.subjectStabilityen_US
dc.subjectImplantsen_US
dc.subjectTitaniumen_US
dc.subjectBoneen_US
dc.titleDetermination of the Optimum Torque to Tighten the Smartpegs of Magnetic Resonance Frequency Analyses Devices: An Ex Vivo Studyen_US