Three-dimensional evaluation of the effects of Bionator and Forsus appliances on oropharyngeal airway volume in patients with mandibular retrognathia

dc.authoridMeric, Pamir/0000-0002-4655-5664
dc.authoridKaradede, Mehmet Irfan/0000-0002-4749-2167
dc.authorwosidMeriç, Pamir/AAF-2482-2021
dc.contributor.authorMeric, Pamir
dc.contributor.authorKaradede, Mehmet Irfan
dc.date.accessioned2024-06-12T11:11:45Z
dc.date.available2024-06-12T11:11:45Z
dc.date.issued2023
dc.departmentTrakya Üniversitesien_US
dc.description.abstractObjectiveTo evaluate whether there is a difference between the effects of Bionator and Forsus appliances on airway volume.MethodsForty patients with mandibular retrognathia were divided into two groups. The Bionator appliance was applied to Group 1, while the Forsus FRD EZ2 appliance was applied to Group 2. Three-dimensional images were captured before and after functional appliance use in both groups. Dolphin 3D software was used for airway measurements.ResultsNo statistically significant difference was found between the groups in terms of volumetric and area measurements. There was a statistically significant difference between the minimum axial T and O-N border T measurements of the groups.ConclusionThe use of functional appliances may contribute to an increase in oropharyngeal airway dimensions, but there was no difference between the Bionator and Forsus groups in terms of volumetric measurements.en_US
dc.description.sponsorshipDicle University Scientific Research Projects, Diyarbakir, Turkey (DUBAP ) [09-DH-05]en_US
dc.description.sponsorshipThis study was supported by Dicle University Scientific Research Projects, Diyarbakir, Turkey (DUBAP Project No: 09-DH-05).The authors would like to thank Cagla Sariturk and Cigdem Keles for the statistical analysis of the studyen_US
dc.identifier.doi10.1080/08869634.2022.2147283
dc.identifier.endpage541en_US
dc.identifier.issn0886-9634
dc.identifier.issn2151-0903
dc.identifier.issue6en_US
dc.identifier.pmid36394427en_US
dc.identifier.scopus2-s2.0-85142289075en_US
dc.identifier.scopusqualityQ3en_US
dc.identifier.startpage529en_US
dc.identifier.urihttps://doi.org/10.1080/08869634.2022.2147283
dc.identifier.urihttps://hdl.handle.net/20.500.14551/22907
dc.identifier.volume41en_US
dc.identifier.wosWOS:000889344000001en_US
dc.identifier.wosqualityQ4en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.language.isoenen_US
dc.publisherTaylor & Francis Ltden_US
dc.relation.ispartofCranio-The Journal Of Craniomandibular & Sleep Practiceen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectOropharyngeal Airwayen_US
dc.subjectBionatoren_US
dc.subjectForsusen_US
dc.subjectMandibular Retrognathiaen_US
dc.subjectCone Beam Computed Tomographyen_US
dc.subjectClass-Ii Malocclusionen_US
dc.subjectSkeletal Class-Iien_US
dc.subjectBeam Computed-Tomographyen_US
dc.subjectFunctional Appliancesen_US
dc.subjectOrthopedic Treatmenten_US
dc.subjectCervical-Spineen_US
dc.subjectHead Postureen_US
dc.subjectDimensionsen_US
dc.subjectTherapyen_US
dc.subjectPositionen_US
dc.titleThree-dimensional evaluation of the effects of Bionator and Forsus appliances on oropharyngeal airway volume in patients with mandibular retrognathiaen_US
dc.typeArticleen_US

Dosyalar