Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • DSpace İçeriği
  • Analiz
  • Talep/Soru
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Untch, B" seçeneğine göre listele

Listeleniyor 1 - 1 / 1
Sayfa Başına Sonuç
Sıralama seçenekleri
  • Küçük Resim Yok
    Öğe
    Ecarin clotting time is sensitive to heparinoids: Comparison of two different techniques
    (Lippincott Williams & Wilkins, 2001) Demir, M; Iqbal, O; Untch, B; Hoppensteadt, DA; Gaikwad, BS; Fareed, J
    Ecarin clotting time (ECT) is currently developed for the specific monitoring of antithrombin drugs, such as hirudin, argatroban, and hirulog. Aqueous reagent and dry chemistry technology have become available for ECT monitoring of antithrombin agents. Currently, many heparinoids and heparinomimetic drugs are being developed. These agents activate heparin cofactor II (HCII) and primarily mediate their effects by inhibiting thrombin. Although the test is specific for antithrombin agents, heparin cofactor II-mediated thrombin inhibitors are capable of prolonging the ECT. In order to study the relative effects of some of these agents, ECT was measured in human plasma supplemented with PI-88 (a sulfated pentomanose; Progen Industries Limited, Sydney, Australia), aprosulate, pentosan polysulfate, dermatan sulfate, unfractionated heparin (UFH), and recombinant hirudin (r-hirudin). All agents were supplemented to the citrated-pooled plasma prepared from 10 healthy volunteers at a graded dosage of 0 to 100 mug/ml. These techniques gave comparable results for all of the agents used (PI-88, r(2) = 0.99; r-hirudin, r(2) = 0.98; UFH, r(2) = 0.98; dermatan sulfate, r(2) = 0.95; aprosulate, r(2) = 0.95; pentosan polysulfate, r(2) = 0.94). The relative anticoagulant effects of various agents used on ECT varied widely, exhibiting their potency in the following order: r-hirudin = pentosan polysulfate > dermatan sulfate > PI-88 > aprosulate > UFH. The sensitivity of ECT was adjusted by varying the concentration of the ecarin reagent. The results suggest that HCII-mediated inhibition of thrombin can be detected by using ECT reagents.

| Trakya Üniversitesi | Kütüphane | Açık Erişim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Edirne, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim