Yazar "Sattarpanah, Samira" seçeneğine göre listele
Listeleniyor 1 - 2 / 2
Sayfa Başına Sonuç
Sıralama seçenekleri
Öğe Agreement of Anterior Segment Parameters Between Schiempflug Topography and Swept-Source Optic Coherence Based Optic Biometry in Keratoconus and Healthy Subjects(Lippincott Williams & Wilkins, 2021) Guclu, Hande; Akaray, Irfan; Kaya, Sultan; Sattarpanah, Samira; Cinar, Abdulkadir Can; Sakallioglu, Kursad; Korkmaz, SelcukPurpose: The aim of this study is to compare anterior segment parameters, including corneal thickness (CCT), keratometry and anterior chamber depth (ACD), and white to white corneal diameter (WTW), obtained by Pentacam Schiempflug imaging and intraocular lens (IOL) Master 700 swept-source optic coherence tomography biometry in keratoconus patients and healthy subjects. Methods: This prospective cross-sectional instrument agreement analysis includes 88 eyes of 50 keratoconus patients and 87 eyes of 50 healthy subjects. Biometry was performed using IOL Master 700, and topography was performed using Pentacam. The keratometry values (Kf, Ks, Km, and Kmax), ACD, WTW, CCT, axial length (AL), anterior chamber angle (ACA), and lens thickness (LT) were evaluated. Levels of agreement between devices were evaluated by Bland-Altman plots with 95% limits of agreement. Results: Intraocular lens Master 700 showed higher WTW, ACD, pupil diameter, and CCT values than Pentacam in both the keratoconus and control groups. However, there were no statistically significant differences in flat keratometry (Kf) and steep keratometry (Ks) values between the groups. Conclusion: Pentacam and IOL Master 700 may be used interchangeably in normal eyes and keratoconus eyes for the measurement of keratometry values and axis; however, these two devices should not be considered interchangeable for WTW, ACD, pupil diameter, and CCT measurements in both keratoconus patients and healthy subjects.Öğe Association of Changes in Thickness of Limbal Epithelial and Stroma with Corneal Scars Detected by High-Resolution Anterior Segment Optic Coherence Tomography(Georg Thieme Verlag Kg, 2023) Guclu, Hande; Sattarpanah, Samira; Gurlu, VuslatAim To investigate the corneal central and limbal thickness in cornea scar patients using high-resolution anterior segment optical coherence tomography (AS-OCT) and to determine the changes in the limbal region due to the corneal scar. Also, to evaluate tear film parameters in scar patients. Methods Thirty patients with central corneal scar and 30 control subjects. The control subjects were healthy individuals who came to our clinic for routine ophthalmological examination. They were enrolled in this matched case-control study. Central epithelial thickness (ET), stromal thickness (ST), limbal epithelial thickness (LET), and limbal stromal thickness (LST) were analyzed using high-resolution AS-OCT. For evaluation of the ocular surface, the following techniques were used: tear break-up time (BUT) employing standard sterile strips of fluorescein sodium, Schirmer test- I (SCH), and the Ocular Surface Disease Index (OSDI) Questionnaire. Results The mean central ET of the patient group was 51.5 +/- 12.4 mu m, while the mean central ET of the control group was 59.2 +/- 9.0 mu m. There was a statistically significant difference between patients and controls (p = 0.008). The mean LST of the patients was 747.9 +/- 115.7 mu m, and the mean LST of the controls was 726.3 +/- 79.7 mu m. There was a statistically significant difference between patients and controls according to BUT (p = 0.009) and SCH (p = 0.04). However, there was no significant difference between OSDI results of patients and controls (p = 0.08). Conclusion Corneal monitoring with high-resolution AS-OCT is a simple, noninvasive, useful technique for corneal scar patients. Cornea scars cause decreased ET. This result could be associated with lower tear film parameters in scar patients. The scar length is associated with higher intraocular pressure (IOP) values. Decreased LET and increased LST were detected in scar patients.